D798-?SM|D798-?SM測厚儀探頭|奧林巴斯D798測厚儀探頭|奧林巴斯OLYMPUS/D798-?SM測厚儀探頭|D798-?SM測厚儀雙晶探頭
奧林巴斯D798-?SM測厚儀雙晶探頭|奧林巴斯OLYMPUS/D798-?SM測厚儀雙晶探頭
27MG測厚儀
45MG測厚儀
38DL PLUS測厚儀
MAGNA-MIKE 8600測厚儀
35RDC測厚儀
深圳華清儀器儀表有限公司優(yōu)惠價供應(yīng)奧林巴斯系列產(chǎn)品,具體想了解D791-?RM價格、D791-?RM貨期、D791-?RM實物圖、D791-?RM應(yīng)用等等,請來電與深圳華清儀器無損檢測部,謝謝
Gage Dual Transducers
Request a quote or purchase a transducer by selecting the item number.
Item Number | Part Code | Frequency (MHz) | Connector Type | Connector Location | Range in Steel (mm) | Range in Steel (in) | Temperature Range °F | Temperature Range °C | Tip Diameter (mm) | Tip Diameter (in) |
---|---|---|---|---|---|---|---|---|---|---|
U8450017 | D797-?SM | 2 | Microdot | Straight | 3.5 - 635 | 0.150 - 25 | -5 - 752 | -20 - 400 | 22.9 | 0.900 |
U8450016 | D797 | 2 | Potted | Right Angle | 3.5 - 635 | 0.150 - 25 | -5 - 752 | -20 - 400 | 22.9 | 0.900 |
U8454038 | D7910 | 5 | Potted | Right Angle | 1.00 - 500.00 | 0.040 - 20.000 | 32 -122 | 0 - 50 | 12.7 | 0.5 |
U8450021 | D799 | 5 | Potted | Right Angle | 1.0 - 508 | 0.040 - 20 | -5 - 300 | -20 - 150 | 11 | 0.434 |
U8450007 | D790-?RL | 5 | LEMO | Right Angle | 1.0 - 508 | 0.040 - 20 | -5 - 932 | -20 - 500 | 11 | 0.434 |
U8450008 | D790-?SL | 5 | LEMO | Straight | 1.0 - 508 | 0.040 - 20 | -5 - 932 | -20 - 500 | 11 | 0.434 |
U8450009 | D790-?SM | 5 | Microdot | Straight | 1.0 - 508 | 0.040 - 20 | -5 - 932 | -20 - 500 | 11 | 0.434 |
U8450011 | D791-?RM | 5 | Microdot | Right Angle | 1.0 - 508 | 0.040 - 20 | -5 - 752 | -20 - 400 | 11 | 0.434 |
U8450002 | D790 | 5 | Potted | Straight | 1.0 - 508 | 0.040 - 20 | -5 - 932 | -20 - 500 | 11 | 0.434 |
U8620225 | MTD705 | 5 | Lepra/Con | Right Angle | 1.0 - 19 | 0.040 - 0.75 | 32 - 122 | 0 - 50 | 5.1 | 0.200 |
U8450010 | D791 | 5 | Potted | Right Angle | 1.0 - 508 | 0.040 - 20 | -5 - 932 | -20 - 500 | 11 | 0.434 |
U8450014 | D794 | 5 | Potted | Straight | 0.75 - 50 | 0.030 - 2 | 32 - 122 | 0 - 50 | 7.2 | 0.283 |
U8450018 | D798 | 7.5 | Potted | Right Angle | 0.71 - 100 | 0.028 - 4 | -5 - 300 | -20 - 150 | 7.2 | 0.283 |
U8450020 | D798-?SM | 7.5 | Microdot | Straight | 0.71 - 100 | 0.028 - 4 | -5 - 300 | -20 - 150 | 7.2 | 0.283 |
U8450019 | D798-?LF | 7.5 | Potted | Right Angle | 0.71 - 100 | 0.028 - 4 | -5 - 300 | -20 - 150 | 8.9 | 0.35 |
U8454013 | D7226 | 7.5 | Potted | Right Angle | 0.71 - 100 | 0.028 - 4 | -5 - 300 | -20 - 150 | 8.9 | 0.35 |
U8450012 | D792 | 10 | Potted | Straight | 0.5 - 25 | 0.020 - 1 | 32 - 122 | 0 - 50 | 7.2 | 0.283 |
U8450013 | D793 | 10 | Potted | Right Angle | 0.5 - 25 | 0.020 - 1 | 32 - 122 | 0 - 50 | 7.2 | 0.283 |
Other Thickness Gage Transducers
For use with 38DL PLUS and 45MG.
* Oxide Software only available for 38DL PLUS.
**E110-SP not available for 45MG.
†Adaptor required for E110 (part number 1/2XA/E110).
Transducer | Part | Freq. | Tip Diameter | Transducer Type | Connector | Range in Steel | Temp. Range | ||||
|
| MHz | in. | mm |
| Type | Location | in. | mm | °F | °C |
V260-SM | U8411019 | 15 | 0.080 | 2 | Sonopen® | Microdot® | Straight | 0.02 - 0.400 | 0.5 - 10 | 32 to 122 | 0 to 50 |
V260-RM | U8411018 | 15 | 0.080 | 2 | Sonopen | Microdot | Right Angle | 0.02 - 0.400 | 0.5 - 10 | 32 to 122 | 0 to 50 |
V260-45 | U8411017 | 15 | 0.080 | 2 | Sonopen | Microdot | 45? Handle | 0.02 - 0.400 | 0.5 - 10 | 32 to 122 | 0 to 50 |
M2017* | U8415002 | 20 | 0.250 | 6.35 | Internal Oxide Scale | Microdot | Right Angle | Steel: | Steel: | 32 to 122 | 0 to 50 |
M2091* | U8415018 | 20 | 0.250 | 6.35 | Replaceable Delay Line Shear Wave | Microdot | Right Angle | Steel: | Steel: | 32 to 122 | 0 to 50 |
E110-SB†** | U8471001 | - | 1.25 | 28.5 | EMAT | BNC | Straight | 0.080 - 5 | 2.0 - 125 | 32 to 176 | 0 to 80 |
Gage Dual Cables
Cable Part Number | Part Code | For Use With | Length | Cable Type | Plug Type | |
|
|
| feet | meters |
|
|
LCMD-316-5B | U8800353 | D790-SM | 5.0 | 1.5 | Standard | Straight |
RLCMD-316-5B | U8800367 | D790-SM | 5.0 | 1.5 | Standard | Rt Angle |
LCMD-178-5B SSA | U8800352 | D790-SM | 5.0 | 1.5 | Armored | Straight |
RLCMD-178-5B SSA | U8800366 | D790-SM | 5.0 | 1.5 | Armored | Rt Angle |
LCLD-316-5G | U8800330 | D790-RL | 5.0 | 1.5 | Standard | Straight |
LCLD-316-5H | U8800331 | D790-SL | 5.0 | 1.5 | Standard | Straight |
LCMD-316-5C | U8800354 | D791-RM | 5.0 | 1.5 | Standard | Straight |
LCMD-316-5D | U8800355 | D797-SM | 5.0 | 1.5 | Standard | Straight |
LCMD-316-5J | U8800357 | D798-SM | 5.0 | 1.5 | Standard | Straight |
LCMD-316-5L | U8800358 | D7906-SM | 5.0 | 1.5 | Standard | Straight |
LCLPD-78-5 | U8800332 | MTD705 | 5.0 | 1.5 | Standard | Straight |
LCM-74-4 | U8800348 | V260-SM, V260-RM, V260-45, M2017 | 4.0 | 1.2 | Standard | - |
LCM-188-4 SSA | U8800342 | V260-SM, V260-RM, V260-45, M2017 | 4.0 | 1.2 | Armored | - |
LCB-74-4 | U8800320 | E110-SB | 4.0 | 1.2 | Standard | - |
The Panametrics-NDT Microscan transducers are frequently used with the Series 25 and Series 35 thickness gages, as well as other commercially available thickness gages, flaw detectors and ultrasonic instrumentation.
Microscan transducer part numbers reflect the connector designation:
RM = Right Angle Microdot®
SM = Straight Microdot
RB = Right Angle BNC
SB = Straight BNC
SU = Straight UHF
When selecting a transducer, please review the chart below or consult the Transducer Frequency Range in the Instruction Manual that was shipped with your gage.
Thickness Gage Model
Transducer Frequency Range
45MG
38DL PLUS
2.0 to 30 MHz
Contact Transducers
One of the advantages of a Panametrics-NDT Microscan contact transducer is its versatility; a single transducer can cover a broad thickness range in many engineering materials. Contact transducers are constructed with the unique WC-5 wearplate for greater durability and a longer life.
Frequency (MHz) | Element inches | Diameter mm | Transducer Part Number | Transducer Part Code | ||
0.5 | 1 | 25 | M101-SB | U8400017 | ||
1 | 1 | 25 | M102-SB | U8400018 | ||
1 | 0.5 | 13 | M103-SB | U8400020 | ||
2.25 | 0.5 | 13 | M106-RM, M106-SM | U8400023, U8400025 | ||
2.25 | 0.5 | 13 | M1036† | U8400019 | ||
5 | 0.5 | 13 | M109-RM, M109-SM | U8400027, U8400028 | ||
5 | 0.25 | 6 | M110-RM, M110-SM, M110H-RM** | U8400030, U8400031, U8400029 | ||
10 | 0.25 | 6 | M112-RM, M112-SM, M112H-RM** | U8400034, U8400035, U8400033 | ||
10 | 0.125 | 3 | M1016 | U8400015 | ||
20 | 0.125 | 3 | M116-RM, M116-SM | U8400038, U8400039 | ||
20 | 0.125 | 3 | M116H-RM* | U8400037 |
RM = Right Angle Microdot; SM = Straight Microdot; SB = Straight BNC
†High Penetration Transducer *Use with Holder, P/N 2133 **Use with Holder, P/N 2132
SONOPEN® Transducers
The Sonopen® transducer has a replaceable delay line that is tapered to a small contact area. This transducer makes reliable thickness measurements in applications such as turbine blades, threads on plastic bottle necks and tight radii on plastic containers. High-temperature Sonopen delay lines are also available.
Frequency | Nominal | Transducer | |||
MHz | inches | mm | Straight | Right Angle | 45° |
15 | 0.125 | 3 | V260-SM | V260-RM | V260-45 |
Tip diameter |
| |
inches | mm | Part Number |
0.08 | 2 | DLP-3 |
0.06 | 1.5 | DLP-302 |
0.08 | 2 | DLP-301* |
*High temperature delay for use up to 350° F (175° C)
Delay Line Transducers
Panametrics-NDT Microscan delay line transducers provide excellent performance on very thin materials, elevated temperatures or in applications that require a high degree of thickness resolution.
Frequency (MHz) | Element inches | Diameter mm | Transducer Part Number | Transducer Part Code | Holders |
0.5 | 1 | 25 | M2008 | U8415001 | - |
2.25 | 0.5 | 13 | M207-RB | U8410017 | - |
5 | 0.5 | 13 | M206-RB | U8410016 | - |
5 | 0.25 | 6 | M201-RM | U8410001 | - |
5 | 0.25 | 6 | M201H-RM | U8411030 | 2127 |
10 | 0.25 | 6 | M202-RM, M202-SM | U8410003, U8410004 | - |
10 | 0.25 | 6 | M202H-RM | U8507023 | 2127 |
10 | 0.125 | 3 | M203-RM, M203-SM | U8410006, U8410007 | - |
20 | 0.125 | 3 | M208-RM, M208-SM | U8410019, U8410020 | - |
20 | 0.125 | 3 | M208H-RM | U8410018 | 2133 |
20 | 0.125 | 3 | M2055* | U8415013 | - |
30 | 0.25 | 6 | V213-BC-RM* | U8411022 | - |
Replaceable Delay Lines
Standard Delay Lines
Standard delay lines are used in many applications. Special conditions such as high surface temperature, curvature of the material or hard-to-access areas may require the use of special delay lines.
Element Diameter | Delay Line Part Number | Maximum Thickness Measurement Limit* | ||||||
Steel Mode 2 | Steel Mode 3 | Plastic Mode 2 | ||||||
inches | mm | inches | mm | inches | mm | inches | mm | |
0.5 | 13 | DLH-2 | 1.0 | 25 | 0.5 | 13 | 0.5 | 13 |
0.25 | 6 | DLH-1 | 1.0 | 25 | 0.5 | 13 | 0.5 | 13 |
0.125 | 3 | DLH-3 | 0.5 | 13 | 0.2 | 5 | 0.2 | 5 |
*Exact range depends on material sound velocity, transducer frequency, part geometry and surface condition.
High Temperature Delay Lines
High temperature delay lines function as a protective buffer between the hot surface of the test piece and the transducer's crystal. At elevated temperatures, intermittent contact is recommended to protect the transducer from thermal damage.
Element Diameter | High Temperature Delays | |||
To 350 °F (175 °C) | To 500 °F (260 °C) | To 900 °F (480 °C) | ||
inches | mm | |||
0.5 | 13 | DLHT-201 | DLHT-2 | DLHT-2G |
0.25 | 6 | DLHT-101 | DLHT-1 | DLHT-1G |
0.125 | 3 | DLHT-301 | DLHT-3 | DLHT-3G |
Immersion Transducers
Panametrics-NDT Microscan immersion transducers are designed to transmit and receive ultrasound in water. Thickness measurements by immersion technique are often preferred when the test piece has a complex geometry or in online applications. Typical offline applications include wall thickness measurements on small diameter plastic or metal tubing, scanned or rotary measurements and thickness measurements on sharply curved parts. Transducer focusing may be necessary depending on the application.
Frequency | Element Diameter | Transducer Part Number | Transducer Part Code | |
(MHz) | inches | mm | ||
2.25 | 0.5 | 13 | M306-SU | U8410027 |
5 | 0.5 | 13 | M309-SU | U8420001 |
5 | 0.25 | 6 | M310-SU | U8420004 |
10 | 0.25 | 6 | M312-SU | U8420008 |
15 | 0.25 | 6 | M313-SU | U8420009 |
20 | 0.125 | 3 | M316-SU | U8420011 |
Bubblers
We offer bubblers for easy implementation of immersion testing. They act as a holder for the transducers to maintain consistent water flow from transducer to test surface, and prevent the accumulation of air bubbles on the transducer face.
Part Number | Opening | Water Path | Fits Transducer Part Number | ||
inches | mm | inches | mm | ||
B100 | 0.125 | 3 | 1.25 | 32 | M310A-SM, M312A-SM, M316A-SM |
B103* | 0.35 | 9 | 0.575 | 14.5 | M310-SU, M312-SU, M313-SU, M316-SU |
B103W* | 0.55 | 14 | 0.775 | 19.7 | M306-SU, M309-SU |
B103A* | 0.35 | 9 | 0.575 | 14.5 | same as B103 |
* The B103 has a V-notch shaped opening; the B103A and B103W are flat. |
Bubbler Transducer Assembly
Handheld bubbler transducers are available in either 20 MHz (V316B) or 10 MHz (V312B). They are immersion transducers that screw onto a bubbler assembly (B120), which has a replaceable stainless steel tip and a water feed tube. They offer high resolution and easy access inspection of thin materials.
RBS-1 Immersion Tank
Panametrics-NDT RBS-1 immersion tank is designed to simplify ultrasonic thickness measurements using immersion techniques. It consists of a clear acrylic tank, a submersible pump and a transducer fixture in a single, portable unit. It is ideal for offline thickness measurements on metal, glass and plastic products such as small containers, pipe or tubing, sheets or plates or machined parts.
Tank
• 5.5 x 12 x 8 in (140 x 305 x 200 mm)
• 0.83 gallon (3.1 liter) capacity
Pump
• 0 to 0.25 gallons (0 to 0.9 liters) per minute
• 115 or 230 V, 30 Watt (voltage range 90 to 135 VAC), 50 to 60 Hz
• Submersible (ground fault interrupter circuit recommended)
Couplants
The use of couplant is almost always necessary to provide acoustic coupling between the transducer and the test piece. We offer various types of couplants to suit virtually all applications.
Part Number | Description | Volume | Application |
A2 AP AQ AG | Propylene Glycol Propylene Glycol Propylene Glycol Propylene Glycol | 2 oz (0.06 liter) 1 pint (0.47 liter) 1 quart (0.95 liter) 1 gallon (3.78 liter) | General purpose couplant for smooth surfaces. Chemically non-reactive; does not evaporate quickly. The maximum recommended temperature is 200 °F (90 °C) |
B2 BQ | Glycerin Glycerin | 2 oz. (0.06 liter) 1 qt. (0.95 liter) | General purpose, more viscous and has a high acoustic impedance making it the preferred couplant for rough surfaces and highly attenuating materials. |
D12 DG D-5G | Gel Type Gel Type Gel Type | 12 oz. (0.35 liter) 1 gal. (3.78 liter) 5 gal. (18.90 liter) | Rough surfaces such as sand-cast metals and fiberglass layups, weld inspections, overhead surfaces or vertical walls. |
E-2 | Ultratherm | 2 oz. (0.06 liter) | 500 °F to 970 °F (260 °C to 520 °C) |
G-2 | Medium Temp | 2 oz. (0.06 liter) | 0 °F to 600 °F (-12 °C to 315 °C) Easy removal at high temperatures. Non-toxic and biodegradable |
SWC | Shear Wave | 4 oz. (0.12 liter) | Normal Incidence Shear Wave, non-toxic, water soluble organic substance of very high viscosity. |
Calibration Test Blocks
Test blocks are necessary for the calibration of ultrasonic thickness gages and should be used to maintain and verify the accuracy, dependability and reliability of ultrasonic measurements. Blocks are held to tighter tolerances than called out in ASTM E797 code. Metric test blocks are available.
Part Number | Material | Steps |
2211E | 304 Stainless Steel | .100, .200, .300, .400 and .500 in |
2212E | 1018 Carbon Steel | .250, .500, .750, .400 and 1.00 in |
2213E | 7075-T6 Aluminum | .100, .200, .300, .400 and .500 in |
2214E | 1018 Carbon Steel | .100, .200, .300, .400 and .500 in |
2214M | 1018 Carbon Steel | 2.5, 5.0, 7.5, 10.0 and 12.5 mm |
?Transducer Cables
Olympus-NDT offers a wide selection of transducer cables suitable for all ultrasonic thickness gaging instrumentation.
Part Number | Connectors | Available Lengths |
LCM-74-X | Small LEMO® 00 to Microdot® | 3 ft (0.9 m), 4 ft (1.2 m), 6 ft (1.8 m) |
LCB-74-X | Small LEMO® 00 to BNC | 3 ft (0.9 m), 4 ft (1.2 m), 6 ft (1.8 m) |
BCM-74-X | BNC to Microdot® | 3 ft (0.9 m), 4 ft (1.2 m), 6 ft (1.8 m) |
LCU-74-X | LEMO® 00 to UHF | 3 ft (0.9 m) |
Standard
• Standard cables are recommended for normal usage.
Heavy Duty - Teflon®
• Heavy duty, Teflon® (HD) transducer cables may provide durability and longer life.
Waterproof
• Waterproof (W) cables are recommended in many tests with immersion transducers. These cables provide a waterproof connection good to about 30 ft (10 m) of fresh water. At greater depths, special cables are available.
Heavy Duty - Armored PVC Jacket
• Heavy duty, armored PVC jacket (HDAP) transducer cables have a spiral stainless steel jacket with a solid PVC coating. Maximum length is 20 ft (7 m).
Heavy Duty - Armored Silicone Jacket
• Heavy duty, armored super flexible silicone jacket (HDAS) transducer cables combine a spiral stainless steel jacket with a heavy silicone coating for great flexibility. Length can be specified up to 20 ft (7 m).
Heavy Duty - Stainless Steel
• Heavy duty, armored stainless steel jacket (SSA) transducer cables are recommended for heavy and industrial use provide flexibility, protection and long life.
相關(guān)產(chǎn)品
免責(zé)聲明
- 凡本網(wǎng)注明“來源:化工儀器網(wǎng)”的所有作品,均為浙江興旺寶明通網(wǎng)絡(luò)有限公司-化工儀器網(wǎng)合法擁有版權(quán)或有權(quán)使用的作品,未經(jīng)本網(wǎng)授權(quán)不得轉(zhuǎn)載、摘編或利用其它方式使用上述作品。已經(jīng)本網(wǎng)授權(quán)使用作品的,應(yīng)在授權(quán)范圍內(nèi)使用,并注明“來源:化工儀器網(wǎng)”。違反上述聲明者,本網(wǎng)將追究其相關(guān)法律責(zé)任。
- 本網(wǎng)轉(zhuǎn)載并注明自其他來源(非化工儀器網(wǎng))的作品,目的在于傳遞更多信息,并不代表本網(wǎng)贊同其觀點和對其真實性負(fù)責(zé),不承擔(dān)此類作品侵權(quán)行為的直接責(zé)任及連帶責(zé)任。其他媒體、網(wǎng)站或個人從本網(wǎng)轉(zhuǎn)載時,必須保留本網(wǎng)注明的作品第一來源,并自負(fù)版權(quán)等法律責(zé)任。
- 如涉及作品內(nèi)容、版權(quán)等問題,請在作品發(fā)表之日起一周內(nèi)與本網(wǎng)聯(lián)系,否則視為放棄相關(guān)權(quán)利。