目錄:上海歐臻機電設備有限公司>>Martens馬騰斯傳感器>>食品衛生級流量計>> MFI447Martens馬騰斯食品衛生級電磁流量計價格
Martens馬騰斯食品衛生級電磁流量計價格
● Ultra compact size
● High accuracy (± 0.5 %) of flow speed > 0.5 m/s (1,6 f/s)
(optional ± 0.3 % for tube diameter < 20 mm)
● No moving parts in the process
● Measurement of fluid, pasty and slurry media
● Turnable transmitter housing (± 170°)
● Programming with touch screen
● EHEDG certified
● CIP-/SIP-capable
● Integrated batch controller (optional)
Technical data
Power supply
Supply voltage : 18..32 V DC
Power consumption : max. 5 W
CE- conformity : EN 61326:05/2007
Ambient condition
Ambient temperature : -20..+50 °C
Climate class : EN 60068-2-38
Vibrations : EN 60068-2-6, GL test2
Approval
EHEDG : Evaluation Report No. 148/18.10.2007
Measuring range : 0..12 m/s (0..33 feet/s)
Min. conductivity : > 5 μS,
> 20 μS for water
Process temperature : -20..120 °C, 140 °C < 30 min
CIP-/SIP-cleaning
Process pressure : -1..10 bar
Process material : coating PFA (FDA conform),
1.4539 electrodes, tube connection
1.4435, seal EPDM (FDA conform)
hygienic design acc. to EHEDG
Process connection : TriClamp, SMS, DIN11851 milk pipe,
DIN11864 Südmo Aseptic connection,
Tuchenhagen flange, APV flange
Material
Tube standard Material 3.1 certificate
DIN 11850 range 1 and 2 1.4404 -
DIN 11866 range A 1.4435 ?
DIN 11866 range B (DIN EN ISO 1127) 1.4435 ?
DIN 11866 range C (ASME) 1.4435 ?
OD-Tube (ASME) 1.4404 -
ISO 2037 1.4404 -
Outputs
Analog : 0/4..20 mA
Switching outputs : 2 x Transistor PNP / NPN programmable
max. 32 V DC,100 mA
programmable as:
- impulse output (max. 10 kHz)
- switching output
- control input
Electrical connection : M12 plug, 5 pole
Isolation : Sensor / supply, output / housing
Housing : electronic housing ? 79 mm
Material : 1.4305
Protection class : IP67 / IP69K
Display : Graphic-LCD background illuminated
Operation : 3 capacitive buttons
Martens馬騰斯食品衛生級電磁流量計價格