| | | HART Loop Converter | | KFD2-HLC-Ex1.D | | | |
|
| | | | | 1-channel isolated barrier, 24 V DC supply (Power Rail), Input HART with transmitter supply, 3 analog outputs 4 mA ... 20 mA, Sink and source mode output, Configurable by keypad | |
|
| | |
| | | HART Loop Converter | | KFD2-HLC-Ex1.D.2W | | | |
|
| | | | | 1-channel isolated barrier, 24 V DC supply (Power Rail), Input HART with transmitter supply, 2 relay outputs (changeover contacts), 3 analog outputs 4 mA ... 20 mA, Sink and source mode output, Configurable by keypad | |
|
| | |
| | | SMART Transmitter Power Supply, Output Current Sink | | KFD2-STC4-Ex1-Y122583 | | | |
|
| | | | | 1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, 0/4 mA ... 20 mA current sink output, Terminals with test points, Up to SIL2 acc. to IEC 61508, Input: 3-wire transmitter, Rated voltage: 20 ... 35 V DC, SIL/IEC 61508, Output signal: 0/4 ... 20 mA (overload > 25 mA), HART transfer, Output, current sink, Input, current source, Explosion protection: Ex-Input | |
|
| | |
| | | SMART Transmitter Power Supply | | KFD2-STC4-Ex1.2O | | | |
|
| | | | | 1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Dual output 0/4 mA ... 20 mA, Terminals with test points, Up to SIL3 acc. to IEC 61508, Input: 3-wire transmitter, Rated voltage: 20 ... 35 V DC, SIL/IEC 61508, Output signal: 0/4 ... 20 mA (overload > 25 mA), HART transfer, Dual output, Input, current source, Explosion protection: Ex-Input | |
|
| | |
| | | SMART Transmitter Power Supply | | KFD2-STC4-Ex2 | | | |
|
| | | | | 2-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire SMART transmitters, Output 0/4 mA ... 20 mA, Terminals with test points, Up to SIL2 acc. to IEC 61508, Input: 2-wire transmitter, Rated voltage: 20 ... 35 V DC | |
|
| | |
| | | SMART Transmitter Power Supply, Output Current Sink | | KFD2-STC4-Ex2-Y132953 | | | |
|
| | | | | 2-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire SMART transmitters, 0/4 mA ... 20 mA current sink output, Terminals with test points, Up to SIL2 acc. to IEC 61508, Input: 2-wire transmitter, Rated voltage: 20 ... 35 V DC | |
|
| | |
| | | SMART Transmitter Power Supply | | KFD2-STV3-Ex1-2 | | | |
|
| | | | | 1-channel isolated barrier, 24 V DC supply (Power Rail), 2-wire SMART transmitter, Output 2 V ... 10 V, SMART capable up to 40 kHz (-1dB), Suitable for Honeywell DE protocol, Terminals with test points, Input: 2-wire transmitter, Rated voltage: 20 ... 35 V DC | |
|
| | |
| | | SMART Transmitter Power Supply | | KFD2-STV4-Ex1-1 | | | |
|
| | | | | 1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/1 V ... 5 V, Terminals with test points, Up to SIL2 acc. to IEC 61508, Input: 3-wire transmitter, Rated voltage: 20 ... 35 V DC | |
|
| | |
| | | SMART Transmitter Power Supply | | KFD2-STV4-Ex1-2 | | | |
|
| | | | | 1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/2 V ... 10 V, Terminals with test points, Up to SIL2 acc. to IEC 61508, Input: 3-wire transmitter, Rated voltage: 20 ... 35 V DC | |
|
| | |
| | | Transmitter Power Supply | | KFU8-CRG2-Ex1.D | | | |
|
| | | | | 1-channel isolated barrier, AC/DC wide range supply, Input 2-wire and 3-wire transmitters and 2-wire current sources, Output 0/4 mA ... 20 mA, 2 relay contact outputs, Programmable high/low alarm, Linearization function (max 20 points), Line fault detection (LFD), Up to SIL2 acc. to IEC 61508, Input: 3-wire transmitter, Rated voltage: 20 ... 90 V DC or 48 ... 253 V AC, Output: 2 x 1 changeover contact + 4-20 mA |
|
|