SPECIFICATIONS |
MODEL | 7305 | 7314 | 7315 | 7316 |
GROUND BOND |
Output AC Current | 3 - 30A | 1 - 40A | 1 - 30A | 1 - 60A |
Output AC Voltage | 6V, Maximum | 8V, Maximum | 6V, Maximum | 12V, Maximum |
Output Frequency | 50Hz/60Hz ±100ppm, User Selection |
SETTINGS |
Max-Limit Range | Resistance | 0- 510mΩ | 0- 120mΩ | 0- 600mΩ | 0- 200mΩ | 0- 150mΩ | 0- 510mΩ | 0- 120mΩ | 0- 600mΩ | 0- 300mΩ | 0- 150mΩ |
AC Current | 3.0- 10.0A | 10.1- 30.0A | 1.00- 10.00A | 10.01- 30.00A | 30.01- 40.00A | 1.00- 10.00A | 10.1- 30.00A | 1.00- 15.00A | 15.01- 30.00A | 30.01- 60.00A |
Resolution | 1mΩ |
Accuracy | Same as Resistance Measurement Accuracy |
Min-Limit Range | Resistance | - | 0- 600mΩ | 0- 200mΩ | 0- 150mΩ | 0- 510mΩ | 0- 120mΩ | 0- 600mΩ | 0- 300mΩ | 0- 150mΩ |
AC Current | - | 1.00- 10.00A | 10.01- 30.00A | 30.01- 40.00A | 1.00- 10.00A | 10.1- 30.00A | 1.00- 15.00A | 15.01- 30.00A | 30.01- 60.00A |
Resolution | 1mΩ |
Accuracy | Same as Resistance Measurement Accuracy |
Lead Resistance Offset | Range | 0 - 100 mΩ, Auto/manual |
Resolution | 1mΩ |
Accuracy | ±(2% of setting +2 counts) |
Dwell Time | Range | 0, 0.5 - 999.9 sec (0 = continuous) |
Resolution | 0.1 sec |
Accuracy | ±(0.1% + 0.05sec) |
MEASUREMENT |
AC Current | Range | 3.0 - 30.0A | 1.00 - 40.00A | 1.00 - 30.00A | 1.00 - 60.00A |
Resolution | 0.1A | 0.01A | 0.01A | 0.01A |
Accuracy | ±(2%of reading +1count) | ±(3%of reading +3counts) | ±(3%of reading +3counts) | ±(3%of reading +3counts) |
Resistance | Range | 0- 510mΩ | 0- 120mΩ | 0- 600mΩ | 0- 600Ω | 0- 200mΩ | 0- 150mΩ | 0- 510mΩ | 0- 510mΩ | 0- 120mΩ | 0- 600mΩ | 0- 600mΩ | 0- 300mΩ | 0- 150mΩ |
3.0- 10.0A | 10.1- 30.0A | 1.00-5.99 A | 6.00- 10.00 A | 10.01- 30.00 A | 30.01- 40.00 A | 1.00- 2.99 A | 3.00- 10.00 A | 10.01- 30.00 A | 1.00- 5.99 A | 6.00- 15.00 A | 15.01- 30.00 A | 30.01- 60.00 A |
Resolution | 1 mΩ |
Accuracy | ±(2%of reading +1count) | ±3% of reading +3 counts) | ±(2% of reading +2 counts) | ±(3% of reading +3counts) | ±(2% of reading +2 counts) | ±3% of reading +3 counts) | ±(2% of reading +2 counts) |
GENERAL |
Input Voltage AC | 115/230Vac±15%, 50/60Hz ± 5%, Fuse 6.3A for 7305/7315 model, 10A for 7314 model, 15A for 7316 model |
PLC Remote Control | Input: Test , Reset,Withstand Processing ,(Memory1.2.3, Interlock for 7314/7315/7316 model only) |
Output: Pass , Fail , Processing , Reset Out , Start Out |
Memory | 5 memories | 10 memories, 3 steps/memory |
Display | 16×2 LCD with back light | 128×64 Graphic LCD |
Key Lock | To prevent unauthorized alteration of the test Parameters |
Calibration | Build-in software and external calibrated meters |
Verification | - | Build-in software driven verification menu to test fault detection circuits |
Alarm Volume Setting | - | Range: 0-9 ;0=OFF, 1 is softest volume, 9 is loudest volume. |
Environment | 0-40℃, 20-80%RH |
Dimension | 280(W)×89(H) ×370(D)mm | 215(W)×89(H) ×430(D)mm | 215(W)×89(H) ×370(D)mm | 430(W)×130(H) ×400(D)mm |
Net Weight | 10Kg | 14Kg | 8.7Kg | 20Kg |
STANDARD ACCESSORIES |
Power Cord(10A) | ×1 | ×1 (15A) |
Fuses | ×2 (Including a spare contained in the fuse holder) | ×1(On Board) |
Interlock Disable Key(1505) | - | ×1 | ×1 | ×1 |
Ground Bond Test Lead 30A ,1.5m(1103) | - | - | ×1 | - |
Ground Bond Return Lead 30A ,1.5m(1104) | - | - | ×1 | - |
Ground Bond Return Lead 30A ,1.6m(1122) | ×1 | - | - | - |
Ground Bond Test Lead 30A,1.6m(1131) | ×1 | - | - | - |
Ground Bond Test Lead 40A,1.6m(1137) | - | ×1 | - | - |
Ground Bond Return Lead 40A,1.6m(1138) | - | ×1 | - | - |
Ground Bond Test Lead 60A,1.65m (1160) | - | - | - | ×1 |
Ground Bond Return Lead 60A,1.65m(1161) | - | - | | | | | | | | |