詳細介紹
SMC減壓閥的特性:
| |||||||||||||||
|
SMC減壓閥的型號:
TUH1208B-100
TUH1208BU-100
TUH1208BU-20
TUS0425B-100
TUS0425B-20
TUS0425BU-100
TUS0425BU-20
TUS0425N-100
TUS0425N-20
TUS0425W-20
TUS0425Y-20
TUS0604B-100
TUS0604B-20
TUS0604BU-100
TUS0604BU-20
TUS0604N-20
TUS0604W-20
TUS0604Y-100-X3
TUS0604Y-20
TUS0805B-100
TUS0805B-20
TUS0805BU-100
TUS0805BU-20
TUS0805N-20
TUS0805W-20
TUS0805Y-20
TUS1065B-100
TUS1065B-20
TUS1065BU-100
TUS1065BU-20
TUS1065N-20
TUS1065Y-20
TUS1208B-100
TUS1208B-20
TUS1208BU-100
TUS1208BU-20
TUS1208N-20
TUS1208Y-20
TU0212B-20
TU0212BU-20
TU0212C-20
TU0212G-20
TU0212R-20
TU0212W-20
TU0212Y-20
TU0425B-100
TU0425B-100(US)
TU0425B-20
TU0425B-20(US)
TU0425BU-100
TU0425BU-20
TU0425BU-20(US)
TU0425BU100(US)
TU0425C-100
TU0425C-20
TU0425C-20(US)
TU0425G-100
TU0425G-20
TU0425R-100
TU0425R-20
TU0425R-20(US)
SMC減壓閥的排除方法
故障現象:壓力波動不穩定
故障分析:
1.油液中混入空氣2.阻尼孔有時堵塞
3.滑閥與閥體內孔圓度超過規定,使閥卡住
4.彈簧變形或在滑閥中卡住,使滑閥移動困難或彈簧太軟
5.鋼球不圓,鋼球與閥座配合不好或錐閥安裝不正確
排除方法:
1.排除油中空氣
2.清理阻尼孔
3.修研閥孔及滑閥
4.更換彈簧
5.更換鋼球或拆開錐閥調整
故障現象:二次壓力升不高
故障分析:
1.外泄漏
2.錐閥與閥座接觸不良
排除方法:
1.更換密封件、緊固螺釘,并保證力矩均力
2.修理或更換
更多詳細信息請點擊:日本SMC真空減壓閥