Item Number | Part Code | Frequency (MHz) | Connector Type | Connector Location | Range in Steel (mm) | Range in Steel (in) | Temperature Range °F | Temperature Range °C | Tip Diameter (mm) | Tip Diameter (in) |
---|---|---|---|---|---|---|---|---|---|---|
U8450017 | D797-?SM | 2 | Microdot | Straight | 3.5 - 635 | 0.150 - 25 | -5 - 752 | -20 - 400 | 22.9 | 0.900 |
U8450016 | D797 | 2 | Potted | Right Angle | 3.5 - 635 | 0.150 - 25 | -5 - 752 | -20 - 400 | 22.9 | 0.900 |
U8454038 | D7910 | 5 | Potted | Right Angle | 1.00 - 500.00 | 0.040 - 20.000 | 32 -122 | 0 - 50 | 12.7 | 0.5 |
U8450021 | D799 | 5 | Potted | Right Angle | 1.0 - 508 | 0.040 - 20 | -5 - 300 | -20 - 150 | 11 | 0.434 |
U8450007 | D790-?RL | 5 | LEMO | Right Angle | 1.0 - 508 | 0.040 - 20 | -5 - 932 | -20 - 500 | 11 | 0.434 |
U8450008 | D790-?SL | 5 | LEMO | Straight | 1.0 - 508 | 0.040 - 20 | -5 - 932 | -20 - 500 | 11 | 0.434 |
U8450009 | D790-?SM | 5 | Microdot | Straight | 1.0 - 508 | 0.040 - 20 | -5 - 932 | -20 - 500 | 11 | 0.434 |
U8450011 | D791-?RM | 5 | Microdot | Right Angle | 1.0 - 508 | 0.040 - 20 | -5 - 752 | -20 - 400 | 11 | 0.434 |
U8450002 | D790 | 5 | Potted | Straight | 1.0 - 508 | 0.040 - 20 | -5 - 932 | -20 - 500 | 11 | 0.434 |
U8620225 | MTD705 | 5 | Lepra/Con | Right Angle | 1.0 - 19 | 0.040 - 0.75 | 32 - 122 | 0 - 50 | 5.1 | 0.200 |
U8450010 | D791 | 5 | Potted | Right Angle | 1.0 - 508 | 0.040 - 20 | -5 - 932 | -20 - 500 | 11 | 0.434 |
U8450014 | D794 | 5 | Potted | Straight | 0.75 - 50 | 0.030 - 2 | 32 - 122 | 0 - 50 | 7.2 | 0.283 |
U8450018 | D798 | 7.5 | Potted | Right Angle | 0.71 - 100 | 0.028 - 4 | -5 - 300 | -20 - 150 | 7.2 | 0.283 |
U8450020 | D798-?SM | 7.5 | Microdot | Straight | 0.71 - 100 | 0.028 - 4 | -5 - 300 | -20 - 150 | 7.2 | 0.283 |
U8450019 | D798-?LF | 7.5 | Potted | Right Angle | 0.71 - 100 | 0.028 - 4 | -5 - 300 | -20 - 150 | 8.9 | 0.35 |
U8454013 | D7226 | 7.5 | Potted | Right Angle | 0.71 - 100 | 0.028 - 4 | -5 - 300 | -20 - 150 | 8.9 | 0.35 |
U8450012 | D792 | 10 | Potted | Straight | 0.5 - 25 | 0.020 - 1 | 32 - 122 | 0 - 50 | 7.2 | 0.283 |
U8450013 | D793 | 10 | Potted | Right Angle | 0.5 - 25 | 0.020 - 1 | 32 - 122 | 0 - 50 | 7.2 | 0.283 |
For use with 38DL PLUS and 45MG.
* Oxide Software only available for 38DL PLUS.
**E110-SP not available for 45MG.
†Adaptor required for E110 (part number 1/2XA/E110).
Transducer | Part | Freq. | Tip Diameter | Transducer Type | Connector | Range in Steel | Temp. Range | ||||
|
| MHz | in. | mm |
| Type | Location | in. | mm | °F | °C |
V260-SM | U8411019 | 15 | 0.080 | 2 | Sonopen® | Microdot® | Straight | 0.02 - 0.400 | 0.5 - 10 | 32 to 122 | 0 to 50 |
V260-RM | U8411018 | 15 | 0.080 | 2 | Sonopen | Microdot | Right Angle | 0.02 - 0.400 | 0.5 - 10 | 32 to 122 | 0 to 50 |
V260-45 | U8411017 | 15 | 0.080 | 2 | Sonopen | Microdot | 45? Handle | 0.02 - 0.400 | 0.5 - 10 | 32 to 122 | 0 to 50 |
M2017* | U8415002 | 20 | 0.250 | 6.35 | Internal Oxide Scale | Microdot | Right Angle | Steel: | Steel: | 32 to 122 | 0 to 50 |
M2091* | U8415018 | 20 | 0.250 | 6.35 | Replaceable Delay Line Shear Wave | Microdot | Right Angle | Steel: | Steel: | 32 to 122 | 0 to 50 |
E110-SB†** | U8471001 | - | 1.25 | 28.5 | EMAT | BNC | Straight | 0.080 - 5 | 2.0 - 125 | 32 to 176 | 0 to 80 |
Cable Part Number | Part Code | For Use With | Length | Cable Type | Plug Type | |
|
|
| feet | meters |
|
|
LCMD-316-5B | U8800353 | D790-SM | 5.0 | 1.5 | Standard | Straight |
RLCMD-316-5B | U8800367 | D790-SM | 5.0 | 1.5 | Standard | Rt Angle |
LCMD-178-5B SSA | U8800352 | D790-SM | 5.0 | 1.5 | Armored | Straight |
RLCMD-178-5B SSA | U8800366 | D790-SM | 5.0 | 1.5 | Armored | Rt Angle |
LCLD-316-5G | U8800330 | D790-RL | 5.0 | 1.5 | Standard | Straight |
LCLD-316-5H | U8800331 | D790-SL | 5.0 | 1.5 | Standard | Straight |
LCMD-316-5C | U8800354 | D791-RM | 5.0 | 1.5 | Standard | Straight |
LCMD-316-5D | U8800355 | D797-SM | 5.0 | 1.5 | Standard | Straight |
LCMD-316-5J | U8800357 | D798-SM | 5.0 | 1.5 | Standard | Straight |
LCMD-316-5L | U8800358 | D7906-SM | 5.0 | 1.5 | Standard | Straight |
LCLPD-78-5 | U8800332 | MTD705 | 5.0 | 1.5 | Standard | Straight |
LCM-74-4 | U8800348 | V260-SM, V260-RM, V260-45, M2017 | 4.0 | 1.2 | Standard | - |
LCM-188-4 SSA | U8800342 | V260-SM, V260-RM, V260-45, M2017 | 4.0 | 1.2 | Armored | - |
LCB-74-4 | U8800320 | E110-SB | 4.0 | 1.2 | Standard | - |
The Panametrics-NDT Microscan transducers are frequently used with the Series 25 and Series 35 thickness gages, as well as other commercially available thickness gages, flaw detectors and ultrasonic instrumentation.
Microscan transducer part numbers reflect the connector designation:
RM = Right Angle Microdot®
SM = Straight Microdot
RB = Right Angle BNC
SB = Straight BNC
SU = Straight UHF
When selecting a transducer, please review the chart below or consult the Transducer Frequency Range in the Instruction Manual that was shipped with your gage.
Thickness Gage Model
Transducer Frequency Range
45MG
38DL PLUS
2.0 to 30 MHz
One of the advantages of a Panametrics-NDT Microscan contact transducer is its versatility; a single transducer can cover a broad thickness range in many engineering materials. Contact transducers are constructed with the unique WC-5 wearplate for greater durability and a longer life.
Frequency (MHz) | Element inches | Diameter mm | Transducer Part Number | Transducer Part Code | ||
0.5 | 1 | 25 | M101-SB | U8400017 | ||
1 | 1 | 25 | M102-SB | U8400018 | ||
1 | 0.5 | 13 | M103-SB | U8400020 | ||
2.25 | 0.5 | 13 | M106-RM, M106-SM | U8400023, U8400025 | ||
2.25 | 0.5 | 13 | M1036† | U8400019 | ||
5 | 0.5 | 13 | M109-RM, M109-SM | U8400027, U8400028 | ||
5 | 0.25 | 6 | M110-RM, M110-SM, M110H-RM** | U8400030, U8400031, U8400029 | ||
10 | 0.25 | 6 | M112-RM, M112-SM, M112H-RM** | U8400034, U8400035, U8400033 | ||
10 | 0.125 | 3 | M1016 | U8400015 | ||
20 | 0.125 | 3 | M116-RM, M116-SM | U8400038, U8400039 | ||
20 | 0.125 | 3 | M116H-RM* | U8400037 |
RM = Right Angle Microdot; SM = Straight Microdot; SB = Straight BNC
†High Penetration Transducer *Use with Holder, P/N 2133 **Use with Holder, P/N 2132
The Sonopen® transducer has a replaceable delay line that is tapered to a small contact area. This transducer makes reliable thickness measurements in applications such as turbine blades, threads on plastic bottle necks and tight radii on plastic containers. High-temperature Sonopen delay lines are also available.
Frequency | Nominal | Transducer | |||
MHz | inches | mm | Straight | Right Angle | 45° |
15 | 0.125 | 3 | V260-SM | V260-RM | V260-45 |
Tip diameter |
| |
inches | mm | Part Number |
0.08 | 2 | DLP-3 |
0.06 | 1.5 | DLP-302 |
0.08 | 2 | DLP-301* |
*High temperature delay for use up to 350° F (175° C)
Panametrics-NDT Microscan delay line transducers provide excellent performance on very thin materials, elevated temperatures or in applications that require a high degree of thickness resolution.
Frequency (MHz) | Element inches | Diameter mm | Transducer Part Number | Transducer Part Code | Holders |
0.5 | 1 | 25 | M2008 | U8415001 | - |
2.25 | 0.5 | 13 | M207-RB | U8410017 | - |
5 | 0.5 | 13 | M206-RB | U8410016 | - |
5 | 0.25 | 6 | M201-RM | U8410001 | - |
5 | 0.25 | 6 | M201H-RM | U8411030 | 2127 |
10 | 0.25 | 6 | M202-RM, M202-SM | U8410003, U8410004 | - |
10 | 0.25 | 6 | M202H-RM | U8507023 | 2127 |
10 | 0.125 | 3 | M203-RM, M203-SM | U8410006, U8410007 | - |
20 | 0.125 | 3 | M208-RM, M208-SM | U8410019, U8410020 | - |
20 | 0.125 | 3 | M208H-RM | U8410018 | 2133 |
20 | 0.125 | 3 | M2055* | U8415013 | - |
30 | 0.25 | 6 | V213-BC-RM* | U8411022 | - |
Standard Delay Lines
Standard delay lines are used in many applications. Special conditions such as high surface temperature, curvature of the material or hard-to-access areas may require the use of special delay lines.
Element Diameter | Delay Line Part Number | Maximum Thickness Measurement Limit* | ||||||
Steel Mode 2 | Steel Mode 3 | Plastic Mode 2 | ||||||
inches | mm | inches | mm | inches | mm | inches | mm | |
0.5 | 13 | DLH-2 | 1.0 | 25 | 0.5 | 13 | 0.5 | 13 |
0.25 | 6 | DLH-1 | 1.0 | 25 | 0.5 | 13 | 0.5 | 13 |
0.125 | 3 | DLH-3 | 0.5 | 13 | 0.2 | 5 | 0.2 | 5 |
*Exact range depends on material sound velocity, transducer frequency, part geometry and surface condition.
High Temperature Delay Lines
High temperature delay lines function as a protective buffer between the hot surface of the test piece and the transducer's crystal. At elevated temperatures, intermittent contact is recommended to protect the transducer from thermal damage.
Element Diameter | High Temperature Delays | |||
To 350 °F (175 °C) | To 500 °F (260 °C) | To 900 °F (480 °C) | ||
inches | mm | |||
0.5 | 13 | DLHT-201 | DLHT-2 | DLHT-2G |
0.25 | 6 | DLHT-101 | DLHT-1 | DLHT-1G |
0.125 | 3 | DLHT-301 | DLHT-3 | DLHT-3G |
Panametrics-NDT Microscan immersion transducers are designed to transmit and receive ultrasound in water. Thickness measurements by immersion technique are often preferred when the test piece has a complex geometry or in online applications. Typical offline applications include wall thickness measurements on small diameter plastic or metal tubing, scanned or rotary measurements and thickness measurements on sharply curved parts. Transducer focusing may be necessary depending on the application.
Frequency | Element Diameter | Transducer Part Number | Transducer Part Code | |
(MHz) | inches | mm | ||
2.25 | 0.5 | 13 | M306-SU | U8410027 |
5 | 0.5 | 13 | M309-SU | U8420001 |
5 | 0.25 | 6 | M310-SU | U8420004 |
10 | 0.25 | 6 | M312-SU | U8420008 |
15 | 0.25 | 6 | M313-SU | U8420009 |
20 | 0.125 | 3 | M316-SU | U8420011 |
We offer bubblers for easy implementation of immersion testing. They act as a holder for the transducers to maintain consistent water flow from transducer to test surface, and prevent the accumulation of air bubbles on the transducer face.
Part Number | Opening | Water Path | Fits Transducer Part Number | ||
inches | mm | inches | mm | ||
B100 | 0.125 | 3 | 1.25 | 32 | M310A-SM, M312A-SM, M316A-SM |
B103* | 0.35 | 9 | 0.575 | 14.5 | M310-SU, M312-SU, M313-SU, M316-SU |
B103W* | 0.55 | 14 | 0.775 | 19.7 | M306-SU, M309-SU |
B103A* | 0.35 | 9 | 0.575 | 14.5 | same as B103 |
* The B103 has a V-notch shaped opening; the B103A and B103W are flat. |
Handheld bubbler transducers are available in either 20 MHz (V316B) or 10 MHz (V312B). They are immersion transducers that screw onto a bubbler assembly (B120), which has a replaceable stainless steel tip and a water feed tube. They offer high resolution and easy access inspection of thin materials.
Panametrics-NDT RBS-1 immersion tank is designed to simplify ultrasonic thickness measurements using immersion techniques. It consists of a clear acrylic tank, a submersible pump and a transducer fixture in a single, portable unit. It is ideal for offline thickness measurements on metal, glass and plastic products such as small containers, pipe or tubing, sheets or plates or machined parts.
Tank
• 5.5 x 12 x 8 in (140 x 305 x 200 mm)
• 0.83 gallon (3.1 liter) capacity
Pump
• 0 to 0.25 gallons (0 to 0.9 liters) per minute
• 115 or 230 V, 30 Watt (voltage range 90 to 135 VAC), 50 to 60 Hz
• Submersible (ground fault interrupter circuit recommended)
The use of couplant is almost always necessary to provide acoustic coupling between the transducer and the test piece. We offer various types of couplants to suit virtually all applications.
Part Number | Description | Volume | Application |
A2 AP AQ AG | Propylene Glycol Propylene Glycol Propylene Glycol Propylene Glycol | 2 oz (0.06 liter) 1 pint (0.47 liter) 1 quart (0.95 liter) 1 gallon (3.78 liter) | General purpose couplant for smooth surfaces. Chemically non-reactive; does not evaporate quickly. The maximum recommended temperature is 200 °F (90 °C) |
B2 BQ | Glycerin Glycerin | 2 oz. (0.06 liter) 1 qt. (0.95 liter) | General purpose, more viscous and has a high acoustic impedance making it the preferred couplant for rough surfaces and highly attenuating materials. |
D12 DG D-5G | Gel Type Gel Type Gel Type | 12 oz. (0.35 liter) 1 gal. (3.78 liter) 5 gal. (18.90 liter) | Rough surfaces such as sand-cast metals and fiberglass layups, weld inspections, overhead surfaces or vertical walls. |
E-2 | Ultratherm | 2 oz. (0.06 liter) | 500 °F to 970 °F (260 °C to 520 °C) |
G-2 | Medium Temp | 2 oz. (0.06 liter) | 0 °F to 600 °F (-12 °C to 315 °C) Easy removal at high temperatures. Non-toxic and biodegradable |
SWC | Shear Wave | 4 oz. (0.12 liter) | Normal Incidence Shear Wave, non-toxic, water soluble organic substance of very high viscosity. |
Test blocks are necessary for the calibration of ultrasonic thickness gages and should be used to maintain and verify the accuracy, dependability and reliability of ultrasonic measurements. Blocks are held to tighter tolerances than called out in ASTM E797 code. Metric test blocks are available.
Part Number | Material | Steps |
2211E | 304 Stainless Steel | .100, .200, .300, .400 and .500 in |
2212E | 1018 Carbon Steel | .250, .500, .750, .400 and 1.00 in |
2213E | 7075-T6 Aluminum | .100, .200, .300, .400 and .500 in |
2214E | 1018 Carbon Steel | .100, .200, .300, .400 and .500 in |
2214M | 1018 Carbon Steel | 2.5, 5.0, 7.5, 10.0 and 12.5 mm |
?Transducer Cables
Olympus-NDT offers a wide selection of transducer cables suitable for all ultrasonic thickness gaging instrumentation.
Part Number | Connectors | Available Lengths |
LCM-74-X | Small LEMO® 00 to Microdot® | 3 ft (0.9 m), 4 ft (1.2 m), 6 ft (1.8 m) |
LCB-74-X | Small LEMO® 00 to BNC | 3 ft (0.9 m), 4 ft (1.2 m), 6 ft (1.8 m) |
BCM-74-X | BNC to Microdot® | 3 ft (0.9 m), 4 ft (1.2 m), 6 ft (1.8 m) |
LCU-74-X | LEMO® 00 to UHF | 3 ft (0.9 m) |
Standard
• Standard cables are recommended for normal usage.
Heavy Duty - Teflon®
• Heavy duty, Teflon® (HD) transducer cables may provide durability and longer life.
Waterproof
• Waterproof (W) cables are recommended in many tests with immersion transducers. These cables provide a waterproof connection good to about 30 ft (10 m) of fresh water. At greater depths, special cables are available.
Heavy Duty - Armored PVC Jacket
• Heavy duty, armored PVC jacket (HDAP) transducer cables have a spiral stainless steel jacket with a solid PVC coating. Maximum length is 20 ft (7 m).
Heavy Duty - Armored Silicone Jacket
• Heavy duty, armored super flexible silicone jacket (HDAS) transducer cables combine a spiral stainless steel jacket with a heavy silicone coating for great flexibility. Length can be specified up to 20 ft (7 m).
Heavy Duty - Stainless Steel
• Heavy duty, armored stainless steel jacket (SSA) transducer cables are recommended for heavy and industrial use provide flexibility, protection and long life.
請輸入賬號
請輸入密碼
請輸驗證碼
以上信息由企業(yè)自行提供,信息內(nèi)容的真實性、準確性和合法性由相關企業(yè)負責,化工儀器網(wǎng)對此不承擔任何保證責任。
溫馨提示:為規(guī)避購買風險,建議您在購買產(chǎn)品前務必確認供應商資質(zhì)及產(chǎn)品質(zhì)量。