Model 211免擦洗紫外臭氧分析儀 Model 211免擦洗紫外臭氧分析儀
- 公司名稱 上海君翼儀器設(shè)備有限公司
- 品牌
- 型號 Model 211免擦洗紫外臭氧分析儀
- 產(chǎn)地
- 廠商性質(zhì) 經(jīng)銷商
- 更新時間 2015/6/11 15:02:09
- 訪問次數(shù) 1468
聯(lián)系方式:王經(jīng)理18621801483 查看聯(lián)系方式
聯(lián)系我們時請說明是化工儀器網(wǎng)上看到的信息,謝謝!
The new Model 212 Scrubberless Ozone Monitor uses the proven ultraviolet (UV) absorption method with an innovative gas-phase scrubber technology to measure ozone virtually free from interferences. In the reference mode, the instrument uses the reaction between ozone and nitric oxide (NO) to selectively remove ozone from the sample. This reaction is orders of magnitude faster than with any other ambient gas, resulting in the removal of only ozone and not potentially interfering compounds that absorb UV light. The instrument is ideally suited for measurements of ozone in heavily polluted air where interference is likely from particulates, mercury, or VOCs. The ozone monitor combines the stability of our proven dual beam ozone monitors with our selective scrubber technology to provide accurate ozone measurements in the most polluted air.
The gas-phase scrubber technology uses NO to quantitatively react with ozone and remove it from the sample. This reaction has long been used as a gas phase titration for the measurement of either NO or O3. In the Scrubberless Ozone Monitor, a low concentration of NO is added to the sample to generate ozone-free, reference air. The light intensity is measured in the reference and sample modes, and the concentration of ozone is calculated directly from Beer's Law. Nitric oxide can be supplied from an external NO cylinder and will provide over a year of gas supply. Alternatively, nitric oxide can be generated inside the instrument using an optional photolytic NO generator and an external cylinder of nitrous oxide (N2O), which is non-toxic, non-corrosive and relatively inexpensive.
All 2B Tech ambient air monitors offer remote instrument operation via RS-232, choice of averaging time (2 s to 1 hr), analog output (0-2.5 V), current output (4-20 mA), internal data logger, and optional flash memory. Our data display and graphing software allows continuous display of data which can be saved for offline analysis
Features
- Virtually interference-free measurement of ambient ozone
- Free of signal quenching interferences inherent to chemiluminescence methods
- DewLine™ for elimination of water vapor interference, a unique feature of 2B Tech instruments
- Inexpensive, simple, and robust instrument design in a 19” rack mount enclosure
- Touchscreen display
- Internal data logger and USB flash memory
- Dual beam optical bench with high precision
- Stable calibration (calibration suggested annually)
- Electronic sample and nitric oxide flow control
- Internal long-life sample pump
- Under evaluation as a Federal Equivalent Method (FEM)
- Convenient user interface, including remote operation via RS-232 communication
- Optional internal NO generator using non-toxic, noncorrosive nitrous oxide (N2O)
Options
- GPS for continuous logging of latitude, longitude and altitude
- External particle filter
Specifications
Measurement Principle | UV Absorption at 254 nm; Dual Beam |
Linear Dynamic Range | 0.5 ppb to 2.0 ppm |
Resolution | 0.1 ppb |
Precision (1σ; rms noise) | Greater of 0.5 ppb or 1% of reading for 10-s average |
Accuracy | Greater of 1.0 ppb or 2% of reading |
Limit of Detection (2σ) | 1.0 ppb |
NIST-Traceable Calibration | Yes |
Flow Rate (nominal) | ~2 Liter/min |
Flow Rate Requirement | >1.2 L/min |
Baseline Drift | <1 ppb/day |
Sensitivity Drift | <0.5%/day |
Measurement Time, Frequency | 2 s, 0.5 Hz |
Response Time, 100% of Step Change | 4 s for 2-s averaging; 20 s for 10-s averaging |
Averaging Times | 2 s, 10 s, 1 min, 5 min, 1 hr |
Internal Data Logger Capacity | 14,336 lines (10 s avg. = 1.4 days; 1 min avg = 10 days; 5 min avg = 1.4 mo; 1 hr avg = 1.6 yr); Virtually unlimited capacity with USB Flash Drive |
Ozone Units | ppb, ppm, pphm, µg m-3, mg m-3 |
Pressure Units | mbar, torr |
Temperature Units | °C, K |
T and P Corrected | Yes |
Operating Temperature Range | 10 to 50 °C |
Operating Altitude Range | ~0-30 km (~30-1000 mbar) |
Power Requirement; Supplied by Battery or 110/220 VAC Power Pack | 12 V dc or 120/240 V ac, 1.1 A at 12 V, 13 watt; 8 watt with Touch Screen off |
Size | Rackmount: 17" w x 14.5" d x 5.5" h (43 x 37 x 14 cm) |
Weight | 14.3 lb (6.5 kg) |
Analog Inputs for Internal Logging of Other Instruments | 3 Analog Inputs, 0-2.5 V; For example could log external T, P and RH |
Data Outputs | Touch Screen Display, USB, RS232, 0-2.5 V Analog, Optional 4-20 mA Analog |
Data Transfer Baud Rates | 1200, 2400, 4800, 19200 |
Output Ranges | User Defined Scaling Factor in Menu |
DewLine™ | Yes |
Long Life Pump | Yes, 20,000 hr |
Flow Meter | Yes |
Options | GPS, Lamp Heater; Bluetooth for wireless data transmission |
System Includes
- Model 211 Scrubberless Ozone Monitor
- AC Power Adapter (100-240 VAC to 12 VDC) with Country-Specific Plug
- Zeroing Cartridge
- Operation Manual on CD
- Calibration Data and NIST-Traceable Calibration Certificate
- Instrument Birth Certificate
- One Year Warranty
相關(guān)分類
- 煙氣分析儀
- 甲醛分析儀
- 粉塵測定儀/粉塵儀
- 紅外線氣體分析儀
- 多組分氣體分析儀
- 一氧化碳分析儀
- 二氧化碳分析儀
- 氨氣分析儀/氨分析儀
- 汽車尾氣分析儀
- 有毒有害氣體監(jiān)測儀
- 煙氣/大氣重金屬在線分析儀
- 高純氣/特氣分析系統(tǒng)
- VOC檢測儀/TVOC檢測儀
- 臭氧分析儀(O3)
- 熱導(dǎo)式氣體分析儀
- CO、SO2、HCL、NOX、空氣檢測儀
- PM2.5/PM10/PM1/TSP大氣顆粒物監(jiān)測儀
- 甲烷/非甲烷烴檢測儀
- 氮氧化物分析儀(NOX)
- 油煙檢測儀
- 惡臭測定儀
- 粉塵采樣器
- 氣體采樣器/大氣采樣器
- 粒子計數(shù)器
- 煙塵采樣器、煙氣采樣器
- 顆粒物采樣器
- 零氣發(fā)生器
- TSP采樣器
- 空氣微生物采樣器
- PM2.5采樣器
- PM10采樣器
- 粗、細(xì)顆粒物雙道采樣器
- 二噁英采樣儀/二噁英采樣器
- 酸雨采樣器
- 激光雷達(dá)
- 太陽光度計
- 塵量分析儀
- 氣體稀釋儀
- 煙度計
- 氣溶膠
- 氣體在線自動監(jiān)測系統(tǒng)
- 灰霾監(jiān)測系統(tǒng)
- 空氣質(zhì)量自動監(jiān)測系統(tǒng)
- 煙氣汞連續(xù)監(jiān)測系統(tǒng)
- 氣體報警器/探測器/傳感器
- 環(huán)境污染事故應(yīng)急監(jiān)測儀器
- 溫室氣體監(jiān)測儀
- 蘇瑪罐采樣器
- 揚(yáng)塵監(jiān)測儀
- 降水/降塵自動采樣監(jiān)測儀
- 煙氣汞采樣器
- 氨逃逸在線監(jiān)測系統(tǒng)
- 粒徑譜儀
- 其它氣體檢測