WZPK-298鎧裝熱電阻利用物質(zhì)在溫度變化時(shí),其電阻也隨著發(fā)生變化的特征來(lái)測(cè)量溫度的。當(dāng)阻值變化時(shí),工作儀表便顯 示出阻值所對(duì)應(yīng)的溫度值。
型號(hào) | 分度號(hào) | 測(cè)量范圍℃ | 精確等級(jí) | 允差 |
WZPK | Pt100 | -200~+500 | * | ±(0.15+0.002│t│) |
B級(jí) | ±(0.30+0.005│t│) |
熱相應(yīng)時(shí)間
套管直徑 | 熱響時(shí)間τ0.5S |
φ3 | ≤3 |
φ4 | ≤5 |
φ5 | ≤6 |
φ6 | ≤8 |
φ8 | ≤10 |
WZPK-298鎧裝熱電阻型號(hào)及規(guī)格
型號(hào) | 分度號(hào) | 測(cè)量范圍℃ | 精度等級(jí) | 安裝固定裝置 |
WZPK-193 | Pt100 | -200~+500 | *或B級(jí) | 無(wú)固定裝置 |
WZPK-194 |
WZPK-195 |
WZPK-196 |
WZPK-198 |
WZPK2-194 |
WZPK2-195 |
WZPK2-196 |
WZPK2-198 |
WZPK-293 | 固定卡套螺紋 |
WZPK-294 |
WZPK-295 |
WZPK-296 |
WZPK-298 |
WZPK2-294 |
WZPK2-295 |
WZPK2-296 |
WZPK2-298 |
WZPK-393 | 可動(dòng)卡套螺紋 |
WZPK-394 |
WZPK-395 |
WZPK-396 |
WZPK-398 |
WZPK2-394 |
WZPK2-395 |
WZPK2-396 |
WZPK2-398 |
WZPK-493 | 固定卡套法蘭 |
WZPK-494 |
WZPK-495 |
WZPK-496 |
WZPK-498 |
WZPK2-494 |
WZPK2-495 |
WZPK2-496 |
WZPK2-498 |
WZPK-593 | 可動(dòng)卡套法蘭 |
WZPK-594 |
WZPK-595 |
WZPK-596 |
WZPK-598 |
WZPK2-594 |
WZPK2-595 |
WZPK2-596 |
WZPK2-598 |
訂貨須知:1)型號(hào)2)分度號(hào)3)精度等級(jí)4)安裝固定形式5)長(zhǎng)度或者總長(zhǎng)
引線主要有三種方式:
二線制:在熱電阻的兩端各連接一根導(dǎo)線來(lái)引出電阻信號(hào)的方式叫二線制:這種引線方法很簡(jiǎn)單,但由于連接導(dǎo)線必然存在引線電阻r,r大小與導(dǎo)線的材質(zhì)和長(zhǎng)度的因素有關(guān),因此這種引線方式只適用于測(cè)量精度較低的場(chǎng)合
三線制:在熱電阻的根部的一端連接一根引線,另一端連接兩根引線的方式稱(chēng)為三線制,這種方式通常與電橋配套使用,可以較好的消除引線電阻的影響,是工業(yè)過(guò)程控制中的常用的。
四線制:在熱電阻的根部?jī)啥烁鬟B接兩根導(dǎo)線的方式稱(chēng)為四線制,其中兩根引線為熱電阻提供恒定電流I,把R轉(zhuǎn)換成電壓信號(hào)U,再通過(guò)另兩根引線把U引至二次儀表。可見(jiàn)這種引線方式可*消除引線的電阻影響,主要用于高精度的溫度檢測(cè)。
公稱(chēng)壓力
一般是指在常溫下,保護(hù)管所能承受靜態(tài)外壓而不破裂,實(shí)驗(yàn)壓力一般采用公稱(chēng)壓力的1.5倍。實(shí)際上,允許公稱(chēng)壓力不僅與保護(hù)管材料、直徑、壁厚有關(guān),而且還與其結(jié)構(gòu)形式、安裝方法、置入深度以及被測(cè)介質(zhì)的流速、種類(lèi)有關(guān)。
熱響應(yīng)時(shí)間
在溫度出現(xiàn)階躍變化時(shí),熱電阻的輸出變化至相當(dāng)于該階躍變化的50%所需要的時(shí)間,稱(chēng)為熱響應(yīng)時(shí)間,用t0.5表示。
熱電阻絕緣電阻:
常溫絕緣電阻的實(shí)驗(yàn)電壓可取直流10~100V任意值,環(huán)境溫度應(yīng)在15~35℃范圍內(nèi),相對(duì)濕度應(yīng)不大于80%;常溫絕緣值應(yīng)不小于100MΩ。