當前位置:上海境宣實業有限公司>>日本光明北川式氣體檢測管>>氣體快速檢測管>> 159SC氧氣O2氣體測毒管159SC OXYGEN 1.5-24%
室內空氣甲醛檢測管No.713 FORMALDEHYDE 0.01-0
氯乙烯CH2=CHCl氣體測毒管132SC VINYL CHLORID
氯乙烯CH2=CHCl氣體檢知管132SB VINYL CHLORID
氧氣O2氣體測毒管159SC OXYGEN 1.5-24%
1. PERFORMANCE
1) Measuring range :3-24% 1.5-3%
Number of pump strokes 1/2(50ml) 1(100ml)
2) Sampling time :1 minute/1/2 pump stroke
1.5 minutes/1 pump stroke
3) Shelf life :2 years
4) Operating temperature :0~45℃
5) Reading :Direct reading from the scale calibrated by 1 /2 pump stroke
6) Colour change :Black→White
2. RELATIVE STANDARD DEVIATION
RSD-low:5% RSD-mid.:5% RSD-high:5%
3. CHEMICAL REACTI0N
Titanium trichloride is oxidized and Titanium oxide is produced.
O2+TiCI3→TiO2
4. CALIBRATION OF THE TUBE
STANDARD GAS CYLINDER METHOD
5. INTERFERENCE AND CROSS SENSITIVITY
3
6
9
12
15
18
21
24
%
50ml
GAS To pump
(White)
DETECTOR TUBE POSTTREAT TUBE
Tube No.
159SC OXYGEN
(NOTE)
When the concentration is below 3%, 1 pump stroke can be used to determine the lower concentration.
Following formula is available for the actual concentration.
Actual concentration=1/2×Reading value
Substance Interference Coexistence
Sulphur dioxide The accuracy of readings is not
affected.
Carbon dioxide 〃
Nitrogen dioxide 〃
Hydrogen sulphide 〃