PSP103型氣相色譜儀
執行標準:GB/T 17623-1998 GB/T 7252-2001 DL/T 722-2000
PSP103型氣相色譜儀是本公司研制的新一代氣相色譜儀。儀器采用微機自動控制、全鍵盤操作、大屏幕液晶中文顯示,具有控溫精度高、性能穩定可靠、靈敏度高、重復性好等特點。
執行標準:GB/T 17623-1998《絕緣油中溶解氣體組分含量的氣相色譜測定法》
GB/T 7252-2001《變壓器油中溶解氣體分析和判斷導則》
DL/T 722-2000《變壓器油中溶解氣體分析和判斷導則》
儀器采用雙柱并聯分流系統。配有TCD檢測器和雙FID檢測器以及甲烷轉化器,能一次進樣實現油中溶解氣體九組分(H2、O2、N2、CH4、C2H2、C2H4、C2H6、CO、CO2)的全分析??捎糜陔娏ο到y油氣設備內部故障檢測,氫冷發電機冷卻介質分析、六氟化硫(SF6)雜質分析、鍋爐煙氣分析、天然氣分析和環境監測分析等。既可作分析,又可作通用分析,因而成為石油、化工、礦山等系統作氣體分析的zui有效設備。
PSP103型氣相色譜儀
1、溫度范圍
柱室:室溫加10℃~399℃
熱導檢測器:室溫加10℃~300℃
氫焰檢測器:室溫加10℃~350℃
轉化爐:室溫加10℃~399℃
溫度控制精度:±0.1℃
溫度顯示精度:0.1℃
2、TCD檢測器
TCD靈敏度:≥5000mv.ml/mg(正十六烷/異辛烷)
噪聲:≤0.02mV
漂移:≤0.05mV/30min
3、FID檢測器
檢測限:≤5×10-12g/s(正十六烷/異辛烷)
噪聲:≤0.02mV
漂移:≤0.05mV/30min
4、定性重復性誤差:≤1%
5、定量重復性誤差:≤3%
6、zui低檢測量
H2 :≤2ppm
CO、CO2:≤2ppm
烴類:≤0.1 ppm
PSP103型氣相色譜儀
The PSP103 Gas chromatograph
Implementation of the standards: GB / T 17623-1998 GB / T 7252-2001 DL / T 722-2000
PSP103 type gas chromatograph is the latest development of a new generation of gas chromatograph. The instrument uses a microcomputer automatic control, full keyboard, large screen LCD Chinese display with high precision temperature control, stable and reliable performance, high sensitivity, good repeatability.
Implementation of the standards: GB / T 17623-1998 "component content of dissolved gases in the insulating oil gas chromatographic method
GB / T 7252-2001 "transformer oil dissolved gas analysis and judgment guide
DL / T 722-2000 "transformer oil dissolved gas analysis and judgment Guidelines
The instrument uses a double column parallel shunt system. Equipped with a TCD detector and dual FID detector, as well as the conversion of methane, a single injection Dissolved Gas nine components (H2, O2, N2, CH4, C2H2, C2H4, C2H6, CO, CO2) of the full analysis. Power system can be used for oil and gas equipment internal fault detection, hydrogen-cooled generator cooling medium, and sulfur hexafluoride (SF6) impurity analysis, boiler flue gas analysis, gas analysis and environmental monitoring and analysis. Both exclusive analysis, but also for the general analysis, and thus become the most effective equipment for the petroleum, chemical, mining and other systems for gas analysis.
1, the temperature range
The column room: room temperature and 10 ℃ ~ 399 ℃
Thermal conductivity detector: room temperature and 10 ℃ ~ 300 ℃
Hydrogen flame detector: room temperature plus 10 ° C to 350 ° C
The conversion furnace: room temperature plus 10 ℃ ~ 399 ℃
Temperature control accuracy: ± 0.1 ℃
Temperature display accuracy: 0.1 ° C
2, TCD detector
TCD sensitivity: ≥ 5000mv.ml/mg (n-hexadecane / isooctane)
Noise: ≤ 0.02mV
Drift: ≤ 0.05mV/30min
3, FID detector
Detection limit: ≤ 5 × 10-12g / s (n-hexadecane / isooctane)
Noise: ≤ 0.02mV
Drift: ≤ 0.05mV/30min
Qualitative repeatability error: ≤ 1%
Quantitative repeatability error: ≤ 3%
6, the lowest detectable amount
H2: ≤ 2ppm
CO, CO2: ≤ 2ppm
Hydrocarbons: ≤ 0.1 ppm