呼吸道病原體21種多重檢試劑盒(PCR方法)
【簡單介紹】
【詳細說明】
呼吸道病原體21種多重檢試劑盒(PCR方法)
廣州健侖生物科技有限公司
準備使用lyo master混合物(每個8孔帶)用于檢測:甲型流感,甲型流感(H1N1),乙型流感,冠狀病毒NL63,229E,OC43和HKU1,副流感1,2,3和4,人偏肺病毒 A和B,鼻病毒,呼吸道合胞病毒A和B,腺病毒,腸道病毒,小RNA病毒,博卡病毒,肺炎支原體包括內部對照。
Ready to use lyo master mix (8-well strips each) for detection of: influenza A, influenza A (H1N1)swl, influenza B, coronaviruses NL63, 229E, OC43 and HKU1, parainfluenza 1, 2, 3 and 4, human metapneumovirus A and B, rhinovirus, respiratory syncytial viruses A and B, adenovirus, enterovirus, parechovirus, bocavirus, Mycoplasma pneumoniae including internal control.
呼吸道病原體21種多重檢試劑盒(PCR方法)
貨號 | 產品名稱 | 英文名稱 |
JL-FT001 | Respiratory pathogens 21 | |
JL-FT002 | 21種呼吸道病原體聯合檢試劑盒(PCR方法) | Respiratory pathogens 21 |
JL-FT003 | 呼吸道病原體25聯檢測試劑盒(PCR方法) | Respiratory pathogens 25 plus |
JL-FT004 | 33種呼吸道病原體聯合檢測試劑盒(PCR方法) | Respiratory pathogens 33 |
JL-FT005 | 8種細菌性肺炎多重檢測試劑盒(PCR方法) | Bacterial pneumoniae CAP |
JL-FT006 | 4種非典型肺炎聯合檢測試劑盒(PCR方法) | Atypical CAP |
JL-FT007 | 肺炎克雷伯菌/銅綠假單胞菌聯合檢測試劑盒(PCR方法) | Bacterial pneumoniae HAP |
JL-FT008 | 博德特氏菌檢測試劑盒(PCR-熒光探針法) | Bordela |
JL-FT009 | 3種流感病毒檢測試劑盒(PCR-熒光探針法) | FLU |
JL-FT010 | 中東呼吸綜合征冠狀病毒(MERS-CoV)檢測試劑盒(PCR方法) | MERS-CoV |
JL-FT011 | MERS-CoV 中東呼吸綜合征冠狀病毒PCR檢測試劑盒 | MERS-CoV |
JL-FT012 | 卡氏肺孢子蟲檢測試劑盒(PCR-熒光探針法) | Pneumocystis jirovecii |
JL-FT013 | 流感甲乙型/人呼吸道合胞病毒AB型四聯檢測試劑盒(PCR-熒光探針法) | FLU/HRSV |
JL-FT014 | 人呼吸道合胞病毒AB型和流感病毒甲乙型聯合檢測PCR試劑盒 | FLU/HRSV |
JL-FT015 | 軍團菌屬三通道多重檢測試劑盒(PCR-熒光探針法) | Legionella |
JL-FT016 | 人冠狀病毒NL63、 229E、OC43 and HKU1聯合檢測試劑盒(PCR方法) | HCoV |
我司還提供其它進口或國產試劑盒:登革熱、瘧疾、流感、A鏈球菌、合胞病毒、腮病毒、乙腦、寨卡、黃熱病、基孔肯雅熱、克錐蟲病、違禁品濫用、肺炎球菌、軍團菌、化妝品檢測、食品安全檢測等試劑盒以及日本生研細菌分型診斷血清、德國SiFin診斷血清、丹麥SSI診斷血清等產品。
歡迎咨詢
歡迎咨詢2042552662
想了解更多的產品及服務請掃描下方二維碼:
【公司名稱】 廣州健侖生物科技有限公司
【市場部】 楊永漢
【】
【騰訊 】 2042552662
【公司地址】 廣州清華科技園創新基地番禺石樓鎮創啟路63號二期2幢101-103室
(3)DAB變質和顯色時間太長:DAB現用現配,如有沉渣應進行過濾后再用。配制好的DAB不應存放時間太長,因為在沒有酶的情況下,過氧化氫也會游離出氧原子與DAB產生反應而降低DAB的效力,未用完的DAB存放在冰箱里幾天后再用這種似乎節約的辦法是不可取的。DAB的顯色在顯微鏡下監控,達到理想的染色程度時立即終止反應。不過當染色片太多時或用染色機時,這樣做似乎不現實,但至少應對一些新的或少用的抗體顯色時進行監控,避免顯色時間過長。
(4)組織變干:修復液溢出后未及時補充液體、染色切片太多、動作太慢、忘記滴液、滴液流失等都是造成組織變干的原因。解決的辦法是操作要認真仔細,采用DAKO筆或PAPPen在組織周圍畫圈,可以有效的避免液體流失,也能提高操作速度。
(5)切片在緩沖液或修復液中浸泡時間太長(大于24小時):原因上不清楚,但現象存在。有的實驗室喜歡前一天將切片脫蠟至修復,第二天加抗體進行免疫組化染色,如果將裝有切片和修復液的容器放在4度冰箱過夜,對結果無明顯影響,如果放在室溫,特別是炎熱的夏天,會出現背景著色,因此,不可存放時間太長。
(6)一抗變質、質量差的多克隆抗體:注意抗體的有效期,過期的抗體要麼不顯色要麼背景著色。用新買的抗體時設立陽性對照和用使用過的抗體作比較。
2、切片邊緣著色
切片邊緣著色也是一種常見的現象,這種現象稱為邊緣效應。產生的原因:(1)組織邊緣與玻片粘貼不牢,邊緣組織松脫漂浮在液體,每次清洗不易將組織下面試劑洗盡所致。解決辦法:制備優質的膠片(APES或多聚賴氨酸),切出盡量薄的組織切片,不厚于4微米,組織的前期處理應規范,盡量避免選用壞死較多的組織。(2)切片上滴加的試劑未充分覆蓋組織,邊緣的試劑容易首先變干,濃度較中心組織高而致染色深。解決辦法:試劑要充分覆蓋組織,應超出組織邊緣 2 mm。用DAKO筆畫圈時,為了避免油劑的影響,畫圈應距組織邊緣3-4 mm。
(3) DAB deterioration and color development time is too long: DAB is best used now with sediment should be filtered before reuse DAB prepared should not be stored for too long, because in the absence of enzymes, peroxidation Hydrogen will also free oxygen atoms react with DAB to reduce the effectiveness of DAB, DUB stored in the refrigerator a few days and then use this seemingly economical approach is not desirable.DAB color is best in the microscope Under the control, to achieve the desired degree of staining immediay terminate the reaction. However, this may not be the case when there are too many dyed sheets or when using a dyeing machine, but at least some new or less used antibodies should be monitored during their color development to avoid excessive color development.
(4) tissue dry: repair fluid overflow after the liquid is not replenished in time, too many dyed slices, action is too slow, forgetting dripping, drip loss and so is the cause of tissue dry out The solution is to operate carefully, Use DAKO pen or PAPPen circle around the organization, can effectively avoid liquid loss, but also improve operating speed.
(5) Slides immersed in buffer or repair fluid for too long (more than 24 hours): reason is unclear, but the phenomenon exists Some laboratories like to deparaffinize the sections the day before to repair, and the next day the antibodies are immunized For histochemical staining, if the container containing sliced ??and reconstituted fluid is placed in a 4-degree refrigerator overnight, there is no noticeable effect on the result. If it is stored at room temperature, especially in the hot summer, background coloring occurs and therefore, it can not be stored for too long .
(6) polyclonal antibodies of the first anti-deterioration, poor quality: pay attention to the validity of the antibody, the expired antibodies either not color or the background color with the new antibody is best to set up a positive control and used antibodies for comparison.
2, slicing edge coloring
Slice edge coloring is also a common phenomenon, this phenomenon is called the edge effect of the reasons: (1) the edge of the tissue and the glass paste is not strong, the edge of tissue loose floating in the liquid, each cleaning is not easy to wash the tissue under the reagent Make the best solution: Prepare high-quality film (APES or polylysine), cut the tissue slices as thin as possible, not thicker than 4 microns, the organization's pre-treatment should be standardized, try to avoid using more necrotic tissue. (2) The reagent dropped on the slice is not enough to cover the tissue. The reagent on the edge is easy to dry at first, and the concentration is higher than the center tissue, resulting in deep staining. The specimen should be adequay covered with tissue and should be 2 mm beyond the edge of the tissue. With DAKO pen circle, in order to avoid the influence of oil, painted circle should be 3-4 mm from the edge of the organization.
相關產品
- 西尼羅河病毒檢測試劑盒(PCR-熒光探針法)
- 寨卡病毒檢測試劑盒(PCR-熒光探針法)
- 克里米亞剛果出血熱病毒熒光PCR檢測試劑盒
- 四種瘧原蟲檢測試劑盒(PCR-熒光探針法)
- 瘧疾核酸檢測試劑盒(PCR-熒光探針法)
- 亞洲熱帶病5聯檢測試劑盒(PCR熒光探針法)
- 非洲熱帶病4聯檢測試劑盒(PCR熒光探針法)
- 核心熱帶病7項聯合檢測試劑盒(PCR方法)
- 神經9項聯合檢測試劑盒(PCR-熒光探針法)
- 細菌性腦膜炎3聯熒光PCR檢測試劑盒
- 細菌性腦膜炎3重核酸檢測試劑盒(PCR方法)
- 病毒性腦膜炎5聯PCR核酸檢測試劑盒
- 病毒性腦膜炎5聯熒光PCR檢測試劑盒
- 戊型肝炎病毒檢測試劑盒(PCR-熒光探針法)
- PCR試劑沙眼衣原體/淋球菌/生殖支原體檢測試劑盒
- 核酸試劑艱難梭菌多重檢測試劑盒(PCR-熒光探針法)
- 核酸試劑諾如病毒G1/G2分型雙重熒光PCR檢測試劑盒
- 諾如病毒G1/G2檢測試劑盒(PCR-熒光探針法)
- PCR核酸試劑糞便寄生蟲多重檢測PCR熒光試劑盒
- PCR核酸試劑細菌性腸胃炎菌屬9聯PCR熒光檢測試劑盒
- PCR試劑細菌性腸胃炎的9種菌屬PCR核酸檢測試劑盒
- PCR試劑六聯病毒性胃腸炎PCR核酸檢測試劑盒
- PCR試劑病毒性胃腸炎的6種病原體核酸檢測試劑盒
- PCR試劑病毒性胃腸炎三重核酸檢測試劑盒(PCR方法)
- PCR試劑腸道病毒/帕氏病毒/腺病毒核酸檢測試劑盒
- PCR試劑四種呼吸道病原體多重核酸檢測試劑盒
- PCR試劑4種甲型流感病毒亞型核酸檢測試劑盒
- PCR試劑人腺病毒/偏肺病毒/博卡病毒PCR檢測試劑盒
- 呼吸道病原體16種多重檢試劑盒(PCR方法)
- 軍團菌屬多重檢測試劑盒(PCR-熒光探針法)
- PCR試劑流感病毒AB/合胞病毒AB四聯檢測試劑盒
- PCR試劑流感甲乙型/合胞病毒AB型四重檢測試劑盒
- 卡氏肺孢子蟲檢測試劑盒(PCR-熒光探針法)
- PCR試劑中東呼吸綜合征(MERS-CoV)檢測試劑盒
- 3種流感病毒檢測試劑盒(PCR-熒光探針法)
- 博德特氏菌檢測試劑盒(PCR-熒光探針法)
- PCR熒光探針肺炎克雷伯菌/銅綠假單胞菌聯合檢測試劑盒
- 4種非典型肺炎聯合檢測試劑盒(PCR方法)
- 8種細菌性肺炎多重檢測試劑盒(PCR方法)
- 33種呼吸道病原體檢測試劑盒(PCR方法)
請輸入產品關鍵字:
郵編:510660
聯系人:楊永漢
電話:86-020-82574011
傳真:86-020-32206070
手機:13802525278
留言:發送留言
個性化:www.jianlun45.com
網址:www.jianlun.com
商鋪:http://www.xldjsj.com/st199246/